Hearth and Home Technologies Wood Burning Fireplace HST-42D User Manual

Page 24

Advertising
background image

24

Chimney must extend
beyond combustible
roof structure

Maintain minimum
height of chimney
above roof

Additional
support for
tall chimneys

Install roof flashing
according to minimum
requirements

Maintain minimum
clearances to
combustibles as
specified

Offsets/returns
may not exceed
30° from vertical

Lock chimney
sections together
firmly to resist
movement

Ceiling firestops
are required where
chimney passes
through ceiling or
floor

Support straps for returns
must be secured to
adequate framing

Termination Cap

Storm Collar

Offsets and returns must
be secured with the screws
provided (outer pipe only)

Figure 8.1 Typical Chimney System - Guidelines for Chimney System Installation

8

8

Chimney Assembly

NOTICE: Chimney performance may vary.
• Trees, buildings, roof lines and wind conditions affect

performance.

• Chimney height may need adjustment if smoking or

overdraft occurs.

Heat & Glo • HST-42D • 27177 • Rev AB • 11/08