42

Firebox

Repack
Insulation
Knockout

Combustible
Materials

Maintain air clearance
to combustibles.

Gas Line

Combustible materials
may be located at zero
clearance to gas line
beyond 4 in. (102 mm)
from fireplace side.

Gas Line

1 1/2 in. (38 mm)
air space around
pipe

Refractory

Seal with
fireplace mortar
or non-combust-
ible sealant

4 in.

(102 mm)

Outer Shell
of Fireplace

Figure 12.1 Gas Line Installation

12

12

Accessories

A. Gas Log/Lighter Provision

WARNING! Fire and/or Asphyxiation Risk! Use with
solid wood fuel or decorative gas appliance only. Gas fi re
generates fumes.
DO NOT install unvented gas logs
• Damper must be locked fully open when gas logs are

installed

A certifi ed gas log lighter or decorative gas log set can be
installed in this fi replace.

• Maximum input is 100,000 BTU/hr.
• Decorative gas appliance must be certifi ed to ANSI

Z21.60 “Standard for Decorative Gas Appliances for
Installation in Vented Fireplaces”.

• Must be installed in accordance with the National Fuel

Gas Code, ANSI Z223.1.

• A gas log set must incorporate a gas shutoff.
• Gas Log set requires the damper to be locked fully

open.

• A listed automatic damper system with safety interlock

may be used in this fi replace with only compatible,
listed gas log sets. See damper system manufacturer’s
insturctions.

• Knockouts are provided on both sides of the fi replace

and in refractories for 1/2 in. (13 mm) iron pipe.

• Seal refractory around pipe with fi replace mortar or a

non-combustible sealant.

B. Wood Burning Inserts

WARNING! Risk of Fire! Improper installation of wood in-
serts may cause fi replace or chimney system to overheat.

If a wood burning insert is being installed in this fi replace,
Hearth & Home Technologies recommends full reline of
the chimney.

• Cooling air openings at the top of the chimney must not

be obstructed in any manner.

• Hearth & Home Technologies recommends securing the

reline at the top of the fl ue and using the cap certifi ed for
use with this fi replace system.

Heat & Glo • HST-42D • 27177 • Rev AB • 11/08