IMAGETEAM™ 2020/5620 System Manual
10 - 9
Trigger Mode
*Manual Trigger
TRGMOD0
Read Time-Out (0 - 300,000
ms) *0
TRGSTO####
Scanner Power Time-Out
Timer (1 - 10,800 seconds)
*3600
BT_LPT#####
Automatic Trigger
TRGMOD1
Presentation Mode
TRGMOD3
Hands Free Time-Out (0-
300,000 seconds) *5000
TRGPTO####
##
Reread Delay
Short (500 ms)
DLYRRD500
*Medium (750 ms)
DLYRRD750
Long (1000 ms)
DLYRRD1000
Extra Long (2000 ms)
DLYRRD3000
User-Specified Reread
Delay
Range 0 - 30,000 ms
DLYRRD####
#
Centering
Centering On
DECWIN1
*Centering Off
DECWIN0
Left of Centering Window *40
DECLFT###
Right of Centering Window *60
DECRGT###
Output Sequence Editor
Enter Sequence
SEQBLK
Default Sequence
SEQDFT
Require Output Sequence
Required
SEQ_EN2
On/Not Required
SEQ_EN1
*Off
SEQ_EN0
Multiple Symbols
On
SHOTGN1
*Off
SHOTGN0
No Read
On
SHWNRD1
*Off
SHWNRD0
Video Reverse
On
VIDREV1
*Off
VIDREV0
Prefix/Suffix Selections
Add CR Suffix to All Symbologies
VSUFCR
Selection
Setting
* Indicates default
Serial
Command
# Indicates a
numeric entry