Scanner trigger modes, Manual/serial trigger, low power, Scanner trigger modes -4 – Hand Held Products 2020/5620 User Manual

Page 58: Manual/serial trigger, low power -4

Advertising
background image

3 - 4

IMAGETEAM™ 2020/5620 System Manual

Scanner Trigger Modes

Manual/Serial Trigger, Low Power

You can activate the scanner either by pressing the trigger, or using a serial
trigger command (see

"Trigger Commands"

on page 10-4). When in manual

trigger mode, the scanner scans until a bar code is read, or until the trigger is
released.

When in serial mode, the scanner scans until a bar code has been read or until
the deactivate command is sent. In serial mode, the scanner can also be set to
turn itself off after a specified time has elapsed (see

Read Time-Out (Serial

Trigger Mode)

, which follows).

Read Time-Out (Serial Trigger Mode)

Use this selection to set a time-out (in milliseconds) of the scanner’s trigger when
using serial commands to trigger the scanner. Once the scanner has timed out,
you can activate the scanner either by pressing the trigger or using a serial
trigger command. After scanning the Read Time-Out bar code, set the time-out
duration (from 0-300,000 milliseconds) by scanning digits on the

Programming

Chart

inside the back cover, then scanning Save.

Default = 0 ms (no time-out).

Scanner Power Time-Out Timer

Note: The Scanner Power Time-out Timer option only applies to Manual/Serial

Trigger.

When there is no activity within a specified time period, the scanner enters low
power mode. Scan the Scanner Power Time-Out bar code to change the time-
out duration (in seconds). Then scan the digit value of the duration (from 1-
10,800 seconds) and the Save bar codes on the

Programming Chart

inside the

back cover of this manual.

Default = 3600 seconds (1 hour).

* Manual/Serial Trigger

Read Time-Out

Advertising