Replacing the it2020 interface cable, Troubleshooting base, Replacing the it2020 interface cable: -2 – Hand Held Products 2020/5620 User Manual

Page 152: Troubleshooting base -2, Changing the it5620 battery

Advertising
background image

12 - 2

IMAGETEAM™ 2020/5620 System Manual

Replacing the IT2020 Interface Cable:

1. Turn the power to the host system

OFF.

2. Disconnect the base’s cable from the

terminal or computer.

3. Turn the base upside down.

4. Pull the connector out while

maintaining pressure on the connector
release clip.

5. Replace with the new cable.

Insert the connector into the opening
and press firmly. The connector is
keyed to go in only one way, and will
click into place.

Changing the IT5620
Battery:

1. Remove the screw on the end

cap.

2. Remove the battery from the

handle.

3. Insert battery.

4. Replace end cap and screw.

Troubleshooting Base

If your base is not functioning
properly, review the following
troubleshooting guidelines to try to isolate the problem.

Is the red LED on?

If the red LED isn’t illuminated, check that:

The power cable is connected properly and there is power at the power
source.

The host system power is on (if external power isn’t used).

Is the green LED on?

If the

green LED isn’t illuminated, check that:

The scanner is correctly placed in the base.

End Cap

Advertising