Out-of-range alarm, Duration, Alarm sound type – Hand Held Products 2020/5620 User Manual

Page 24: Out-of-range alarm -8, Duration -8 alarm sound type -8

Advertising
background image

1 - 8

IMAGETEAM™ 2020/5620 System Manual

Out-of-Range Alarm

Duration

If your scanner is out range of the base, an alarm sounds from both your base
and scanner. To activate the alarm options for the scanner or the base and to
set the alarm duration, scan the appropriate bar code below and then set the
time-out duration (from 0-3000 seconds) by scanning digits on the

Programming

Chart

inside the back cover, then scanning Save.

Default = 0 sec (no alarm).

Note: If you are out of range when you scan a bar code, you will receive an error

beep even if you do not have the alarm set. You receive the error beep
since the data could not be communicated to the base or the host.

Alarm Sound Type

If you have set the out-of-range alarm enabled, you may change the alarm type
for the scanner or base by scanning the appropriate bar code below and then
scanning a digit (0-7) bar code and the Save bar code on the

Programming Chart

inside the back cover of this manual.

Default = 0. Set the sound type to fit your

application.

Base Duration Alarm

Scanner Duration Alarm

Base Alarm Type

Scanner Alarm Type