T8600D CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATS

69-1409—1

2

Wallplate Installation

The thermostat can be mounted horizontally on the wall
or on a 2 in. x 4 in. (50.8 mm x 101.6 mm) wiring box.
Position wallplate horizontally on the wall or on a
2 in. x 4 in. (50.8 mm x 101.6 mm) wiring box.

1. Position and level the wallplate (for appearance

only). The thermostat will function correctly even
when not level.

Fig. 1. Typical location of thermostat.

Fig. 2. Mounting the wallplate.

2. Use a pencil to mark the mounting holes. See Fig.

2.

3. Remove the wallplate from the wall and drill two

3/16 inch (76 mm) holes in the wall (if drywall) as
marked. For firmer material such as plaster, drill
two 7/32 inch (5.56 mm) holes. Gently tap anchors
(provided) into the drilled holes until flush with the
wall.

4. Position the wallplate over the holes, pulling wires

through the wiring opening.

5. Loosely insert the mounting screws into the holes.
6. Tighten mounting screws.

WIRING

All wiring must comply with local electrical codes and
ordinances. Refer to Fig. 3 through 5 for typical hookups.
A letter code is located near each terminal for
identification.

CAUTION

Electrical Hazard.
Can cause electrical shock or equipment
damage.
Disconnect power before wiring.

1. Loosen the terminal screws on the wallplate and

connect the system wires. See Fig. 6.

IMPORTANT

Use 18 gauge, color-coded thermostat cable for
proper wiring.

2. Securely tighten each terminal screw.
3. Push excess wire back into the hole.
4. Plug the hole with nonflammable insulation to

prevent drafts from affecting the thermostat.

Fig. 3. Typical hookup in heat only application.

5 FEET

[1.5 METERS]

YES

NO

NO

NO

M10106

WIRES
THROUGH WALL

WALL

MOUNTING
HOLES

M15044

MOUNTING
SCREWS

WALL
ANCHORS (2)

L1
(HOT)

L2

M10346A

FAN
RELAY

G

THERMOSTAT

HEAT
RELAY

R

RC

W

TRANSFORMER

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.

NOT AVAILABLE ON T8600A MODELS.

1

2

1

2