Honeywell BENDIX/KING KLN 94 User Manual

Page 13

Advertising
background image

B

KLN 94

Rev. 4, Jan/2003 10599I04.CDL

Page 1-3

OBS COS:

OBS resolver cosine. Nominal input impedance
is 33.8 K ohms (AC) and 100 K ohms (DC).

A/C POWER MONITOR:

This pin senses the aircraft power bus voltage.
This high impedance input operates from 0 to
33 V with accuracy of 0.1 V.

CONFIGURATION MODULE: Refer to

Section 2.3.6.2

SIGNAL OUTPUTS:

OBI SYNC, OBI CLOCK, & OBI DATA:

Honeywell Serial Data containing bearing to
the active waypoint.

DATA LOADER/QUICKTUNETM RS 232 OUT: The Data Loader/QuickTune RS 232 output is

designed to communicate with an IBM
compatible personal computer.

GENERAL RS 232 OUT:

The RS 232 output is designed to interface with
certain ARNAV ELTs and certain moving map
displays, and Shadin fuel flow systems (refer to

RS 232 Format Definitions Appendix

).

GPS SENSOR RS 232 OUT:

The GPS Sensor RS 232 output is a buffered
connection to the GPS sensor (Xpress)
transmitter connection to the host processor. It
is designed to interface with a EGPWS, and for
testing.

WAYPOINT ANNUNCIATE:

OPEN = Inactive
LOW = Active (Output can sink up to 250 mA)

MESSAGE ANNUNCIATE:

OPEN = Inactive
LOW = Active (Output can sink up to 250 mA)

APPROACH ACTIVE ANNUNCIATE:

OPEN = Inactive
LOW = Active (Output can sink up to 250 mA)

APPROACH ARM ANNUNCIATE:

OPEN = Inactive
LOW = Active (Output can sink up to 250 mA)

SPARE ANNUNCIATE 1:

Spare annunciators are reserved for future
use.

SPARE ANNUNCIATE 2:

Spare annunciators are reserved for future
use.

ROLL STEERING VALID
N/A on -0101

Valid =

18 V in 28 VDC installations;

10 V in

14 VDC installations. Invalid =

3.5 V in all

installations while sinking 1 mA. Output can
source at least 250 mA.

ROLL STEERING HI
N/A on -0101

Output Range:

550mV per degree of Bank.

2V per degree per second of
Turn Rate.

Advertising