HP STORAGEWORKS SSL1016 User Manual

Page 131

Advertising
background image

Troubleshooting

131

SSL1016 Tape Autoloader Reference Guide

.

Table 14: Error Messages

Error Message

Description

Suggested Repair

00 - 25

General software

flags

Power cycle the autoloader and run the Health test.

Check HP website for firmware updates.

26

Message Send ID

error

Check SCSI Bus cables and terminators.

Make sure the host bus adapter is installed,

detected, and configured properly.

Power cycle autoloader. Repeat checks after power

cycle.

27

Message bad

Check SCSI bus cables and terminators.

Make sure the host bus adapter is installed,

detected, and configured properly.

Power cycle autoloader. Repeat checks after power

cycle.

28

Message parameter

bad

Check host device driver.

Make sure the software application is supported,

has the autoloader correctly configured, and has

the latest patches installed.

Check SCSI bus cables and terminators.

Make sure the host bus adapter is installed,

detected, and configured properly.

Power cycle autoloader. Repeat checks after power

cycle.

29

Invalid element

Check host device driver.

Make sure the software application is supported,

has the autoloader correctly configured, and has

the latest patches installed.

Power cycle autoloader. Repeat checks after power

cycle.

Advertising