2 configuration file download – Hitachi HANDYTONE-486 User Manual

Page 38

Advertising
background image

HandyTone-486 User Manual

Grandstream Networks, Inc.

38

the TFTP server is connected to the device’s LAN port, the firmware upgrade will not work by
design.

7.2

Configuration File Download


Grandstream SIP Device can be configured via Web Interface as well as via Configuration File
through TFTP or HTTP. “Config Server Path” is the TFTP or HTTP server path for configuration file.
It needs to be set to a valid URL, either in FQDN or IP address format. The “Config Server Path” can
be same or different from the “Firmware Server Path”.

A configuration parameter is associated with each particular field in the web configuration page. A
parameter consists of a Capital letter P and 2 to 3 (Could be extended to 4 in the future) digit numeric
numbers. i.e., P2 is associated with “Admin Password” in the ADVANCED SETTINGS page. For a
detailed parameter list, please refer to the corresponding firmware release configuration template.

When Grandstream Device boots up or reboots, it will issue request for configuration file named
“cfgxxxxxxxxxxxx”, where “xxxxxxxxxxxx” is the MAC address of the device, i.e.,
“cfg000b820102ab”. The configuration file name should be in lower cases.


7.3

Firmware and Configuration File Prefix and Postfix


Starting from firmware version 1.0.7.11 for HandyTone-486 Rev 2.0, adding prefix and postfix for
both firmware and configuration file is supported.

Firmware Prefix and Postfix allows device to download the firmware name with the matching Prefix
and Postfix. This makes it the possible to store ALL of the firmware with different version in one
single directory. Similarly, Config File Prefix and Postfix allows device to download the configuration
file with the matching Prefix and Postfix. Thus multiple configuration files for the same device can be
stored in one directory.

In addition, when the field “Check New Firmware only when F/W pre/suffix changes” is set to “Yes”,
the device will only issue firmware upgrade request if there are changes in the firmware Prefix or
Postfix.

7.4

Managing Firmware and Configuration File Download


When “Automatic Upgrade” is set to “Yes”, Service Provider can use P193 (Auto Check Interval, in
minutes, default and minimum is 60 minutes) to have the devices periodically check with either
Firmware Server or Config Server, whenever they are defined. This allows the device periodically
check if there are any new changes need to be taken on a scheduled time. By defining different
intervals in P193 for different devices, Server Provider can spread the Firmware or Configuration File
download in minutes to reduce the Firmware or Provisioning Server load at any given time.

VoIPon www.voipon.co.uk [email protected] Tel: +44 (0)1245 808195 Fax: +44 (0)1245 600030

Advertising