45 degree, Straight out, Castile pellet stove – Hearth and Home Technologies CASTILE-PMH1 User Manual

Page 13: B. through the wall

Advertising
background image

R

September 1, 2008

250-6422E

Page 13

Castile Pellet Stove

12 in.

(305mm)
Minimum

Noncombustible Hearth Pad

Wall
Thimble

Horizontal
Termination
Cap

2 in.

(51mm)

Minimum

6 in.

(152mm)
Minimum

From Glass

Straight Out

45 Degree

B. Through The Wall

Horizontal termination cap must be a minimum of 12 inches.
(305mm) from the wall. Approved for mobile home instal-
lations. Must use 3 or 4 inch (76-102mm) “L” or “PL” listed
pellet venting or listed double wall pipe and a Quadra-Fire
Outside Air Kit in mobile homes.

NOTE:
In Canada, where passage through a wall or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B365

Figure 13.1

Figure 13.2

Wall
Thimble

Illustration shows venting going in both directions.
Choose which one is best for your installation.

2 in. (51mm)

Minimum

2 in.

(51mm)

Minimum

12 in. (305mm)

Minimum

12 in.

(305mm)
Minimum

Advertising