Castile Pellet Stove

*L Exception for Horizontal Installations:

USA INSTALLATIONS: A non-combustible floor protection is
recommended extending beneath the flue pipe when installed
with horizontal venting or under the Top Vent Adapter with
vertical installation.

CANADA INSTALLATIONS: A non-combustible floor pro-
tection extending beneath the flue pipe is required with hori-
zontal venting or under the Top Vent Adapter with vertical
installation.

Must extend 2 inches (51mm) beyond each

side of pipe (shaded area)

C. Hearth Pad Requirements (UL and ULC)

Use a non-combustible floor protector, extending beneath
appliance and to the front, sides and rear as indicated.
Measure front distance “M” from the surface of the glass
door.

Hearth Pad Requirements

Inches

Millimeters

K

Sides

2

51

L*

Back

2

51

M

Front

6

152

L*

K

K

M