250-6422E

September 1, 2008

R

Castile Pellet Stove

Straight Back Against
Wall

Inches

Millimeters

A

Back Wall to Appliance

2

51

B

Side Wall to Appliance

6

152

Corner Installation

Inches

Millimeters

C

Walls to Appliance

2

51

Vertical Installation

Inches

Millimeters

D

Back Wall to Flue Pipe

3

76

E

Side Wall to Cast Top

6

152

F

Back Wall to Appliance

8

203

Installations with:

3 to 3 inch Top Vent Adapter and
3 to 6 inch Offset Adapter Kit

Corner Installation

Inches

Millimeters

G

Walls to Appliance

2

51

H

Side Wall to Flue Pipe

3

76

Alcove Installation

Inches

Millimeters

Minimum Alcove Height

43

1092

Minimum Alcove Side Wall

6

152

Minimum Alcove Width

38

965

Maximum Alcove Depth

36

914

Dimension to Corner

Inches

Millimeters

I

Flue Center Line

10-3/8

264

J

Back of Top Vent Adapter

9-1/8

232

B. Clearances to Combustibles (UL and ULC)

Fire Risk.

Comply with all minimum clearances to
combustibles as specified.

WARNING

Failure to comply may cause house fire.

NOTE:
Illustrations reflect typical installations and are FOR

DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design

preference.

J

I

CL

C

C

D

E

F

G

G

H

H