Combustion blower, Remove 6 screws – Hearth and Home Technologies CASTILE-PMH1 User Manual

Page 32

Advertising
background image

Page 32

250-6422E

September 1, 2008

R

Castile Pellet Stove

2.

Combustion Blower Replacement

NOTE: The convection blower must be removed

before the exhaust blower can be removed.

a. Turn down thermostat, let appliance completely cool and

then unplug appliance before servicing.

b Remove both side curtains by loosening 2 screws (do

not remove) and pull side panels away.

c. Remove 7 screws from the back screen and pivot the top

of the screen toward you leaving the bottom attached to
stove. Figure 32.1.

d. Remove 2 screws to remove the thermostat block and

disconnect the 2 yellow wires.

e. Remove the 2 screws from the power inlet and rotate it

through the hole and out of the screen, leaving the wires
attached.

f. Disconnect the vacuum hose and both wires (orange

and red) from the vacuum switch attached to the rear
screen.

g. Remove both wires from exhaust blower (blue and

double white).

h. Remove 6 screws using a flathead screwdriver or a 1/4"

nutdriver. Retain screws for use on replacement blower.
Figure 32.2.

i.

Remove exhaust blower and gasket.

j.

Install new gasket and blower. Discard blower housing
if not needed.

k. Re-install in reverse order.

Figure 32.1

Combustion

Blower

Remove 7 screws and bend top back
leaving it attached at the bottom.

Remove 6 screws

Figure 31.2

Figure 32.3

Advertising