E. Valve Access

Washer

Figure 6.1 Lift Out Doors

Figure 6.3 Loosen Refractory Retaining Strip

Figure 6.4 Remove Valve Access Panel

Figure 6.5 Remove Exterior Valve Access Panel

Figure 6.6 Connect Manometer

• The gas valve can be accessed behind the cement

refractory panel on the right side of the fi replace.

• Lift doors out and set aside. There is a washer under each

door. Be careful not to loose those washers.

• Use a phillips screwdriver to remove the exterior valve

access panel (remove four screws).

• Use a manometer on the lower out pressure tap. Start

up the fi replace to verify the pressure and adjust as
necessary. Reverse these steps to reassemble before log
positioning.

• Remove logs if access is necessary after installation is

complete. See Section 9.C. Remove logs in reverse order
of set up.

• Remove grate if access is necessary after installation is

complete. (Refer to Section 9.B.)

• Remove two screws on side of pilot shield and remove

shield.

• Remove the inside valve access panel by lifting it up and

out.

Figure 6.2 Remove Pilot Shield

• Use a phillips screwdriver to remove the two screws

securing the refractory retaining strip. Remove the
refractory side panel and set aside.