Heat & Glo LifeStyle Collection • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev J 11/08

Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualifi ed
service technician should perform an appliance check-up at the beginning of each heating season.

Fire Risk
Explosion Risk

Inspect external vent cap regularly.
• Ensure no debris blocks cap.
• Combustible materials blocking cap may

ignite.

• Restricted air flow affects burner

operation.

WARNING

Annual inspection by qualified technician
recommended.
Check:
• Condition of doors, surrounds and fronts.
• Condition of glass, glass assembly and glass

seal.

• Obstructions of combustion and ventilation

air.

• Condition of logs.
• Condition

of

fi rebox.

• Burner ignition and operation.
• Burner air shutter adjustment.
• Gas connections and fi ttings.
• Obstructions of termination cap.
Clean:
• Glass.
• Air passageways, grilles, control

compartment.

• Burner, burner ports.
Risk of:
Fire
• Delayed ignition or explosion
• Exposure to combustion fumes
• Odors

WARNING

Handle glass assembly with care.
Note: Clean glass after initial 3-4 hours

operation. Longer operation without
cleaning glass may cause a permanent
white fi lm on glass.

When cleaning glass door:
• Avoid striking, scratching or slamming

doors.

• Do NOT use abrasive cleaners.
• Use a hard water deposit glass cleaner on

white fi lm.

• Do NOT clean glass when it is hot.
• Turn off appliance after 3-4 hours of

operation and ALLOW TO COOL.

• Remove and clean glass assembly.
• Replace glass assembly and operate

appliance for an additional 12 hours.

Refer to maintenance instructions.

CAUTION

12

12

Maintaining and Servicing the Appliance

Risk of injury or property damage
Before servicing:
• Turn off gas.
• Turn off electricity to appliance.
• Disable remote control, if one is present.
• Ensure appliance is completely cooled.
After Servicing:
• Replace any screen or barrier that was removed.
• Reseal and reinstall any venting removed for

servicing.

WARNING