A. Design and Installation Considerations

Check building codes prior to installation.
• Installation MUST comply with local, regional,

state and national codes and regulations.

• Consult insurance carrier, local building, fire

offi cials or authorities having jurisdiction about
restrictions, installation inspection, and permits.

CAUTION

When planning an appliance installation, it’s necessary to
determine the following information before installing:

• Where the appliance is to be installed.
• Gas supply piping.
• Electrical

wiring.

• Framing

and

fi nishing details.

2

2

Getting Started

Moisture Resistance:

This outdoor fi replace will shed moderate amounts of water,
but is not waterproof. Water and condensing water vapor
may enter the chase under certain conditions.

The fi replace will not perform as an exterior wall. Moisture
penetration must be considered for construction that places
the fi replace in structure walls or on moisture sensitive sur-
faces.

When installed on exterior walls: Hearth & Home Tech-
nologies recommends that the fi replace chase be con-
structed outside the structure’s weather envelope. Where
the platform meets the wall, use a fl ashing detail similar to
that required for attached decks. Chase platforms, including
hearths should slope away from the structure at 1/8 in. to
1/4 in. per foot. The fi replace can be shimmed level.

When installed on surfaces where water may collect or
cause damage:
Hearth & Home Technologies recommends
that a drainage pan be placed under the unit. This can be
constructed of metal, adhesive polymer membrane (such as
ice and water shield) or other suitable materials. A means of
drainage out of the pan such as tubes or weep holes should
be provided. A slope of 1/8 in. to 1/4 in. per foot towards
the drain port is suggested. The fi replace can be shimmed
level.

Hearths should slope away from the front of the fi replace
and chase at 1/8 in. to 1/4 in. per foot. Spark strips must be
on top of any combustible hearth materials used for moisture
management.

These appliances must be installed outdoors.
The Dakota 42-B Series Outdoor Gas Fireplace is designed
for outdoor use. It may also be installed in screened porches
and lanais that meet these minimum requirements:
• Minimum porch area - 96 square feet
• Minimum ceiling height - 84 in.

A minimum of two walls can be screened but must be open
to outside ventilation.

• Minimum screen area - 64 square feet
• Minimum screen top height - 80 in.

Refer to Section 3.B. for clearances.