14

Heat & Glo LifeStyle Collection • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev J 11/08

Battery polarity must be correct or module damage will
occur.

CAUTION

A. Intellifi re Ignition System Wiring

• This appliance is equipped with an Intellifi re control valve

which operates on a 3 volt system.

• This appliance is supplied with a battery pack which is

located in the ON/OFF switch terminal box. A wiring
diagram is shown in Figure 7.1.

• The battery pack requires two D cell batteries (not

included). See Section 12.B. for battery replacement.

7

7

Electrical Information

Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.

CAUTION

Shock Risk
• Replace damaged wire with type 105° C

rated wire.

• Wire must have high temperature

insulation.

WARNING

IGNITION MODULE

3 VAC

GRN

ORG

INTERMITTENT

PILOT

IGNITOR

IGNITION

MODULE

(3V)

ON/OFF

WALL

SWITCH

LOW VOLTAGE

BATTERY

PACK

FLAME SPARKER/

SENSOR

SEE NOTE 1

ORG

WHT

PIGGYBACK

ON/OFF SWITCH

BRN

BRN

VALVE

VALVE

GROUND TO

FIREPLACE

CHASSIS

I

S

BLACK

RED

BATTERY

PACK

Figure 7.1 Intellefi re Pilot Ignition (IPI) Wiring Diagram