Fire Risk.

Hearth extension required to protect
combustible fl oors in front of appliance.

• An 8 inch minimum hearth extension must be constructed

of non-combustible material.

E. Hearth Extension

WARNING

Figure 3.6 Hearth Extension Dimensions

A

B

Cerona-36

in.

41-1/8

8

mm

1045

203

Cerona-42

in.

48-1/8

8

mm

1222

203

A

B

NAILING TABS

(BOTH SIDES)

NON-COMBUSTIBLE

HEARTH EXTENSION

1 in. max.

(25 mm)

8 in. min.
(203 mm)

COMBUSTIBLE
SURFACE

MARBLE, GRANITE, TILE OR
OTHER NON-COMBUSTIBLE
HEARTH EXTENSION

BOTTOM OF

FIREPLACE

Figure 3.7 Fireplace sitting on combustible surface.

Figure 3.8 Fireplace raised a minimum of 6 inches away from
combustible

surface.

BOTTOM OF
FIREPLACE

SURFACE MAY BE COMBUSTIBLE

COMBUSTIBLES

UP TO 1 INCH

THICK ALLOWED

UNDER THE OPENING

6 INCHES

MINIMUM

1 INCH MAX.

TO ALLOW FOR

DOOR CLEARANCE

The base of the fi replace may sit on a combustible surface.
The area in front of the fi replace must be protected by a
noncombustible hearth extension, unless the fi replace is
raised a minimum of 6 inches above the combustible fl oor
or hearth. See fi gures 3.7 and 3.8.