D. Installing Flue Restrictors

Locate the fl ue restrictor and two screws inside the manual
bag. Use the following table to determine which restrictors
to use for the vent run.

Vent Run Vertical

15 ft. - 50 ft.

Cerona-36

1-1/4

Cerona-42

1-1/4

Figure 7.5

• Attach the left and right side pieces to the framing

members. (See Figure 7.3).

• Use a wet or dry towel or soft brush to remove dust or

dirt from facing material.

• Apply a non-combustible adhesive to attach tile,

stone or other non-combustible fi nishing materials per
manufacturer’s instructions.

Figure 7.4 Complete Installation of Non-combustible
Facing

Material

A

B

Cerona-36

in.

43-5/8

50-3/16

mm

1108

1275

Cerona-42

in.

50-5/8

54-3/8

mm

1286

1381

A

B

NON-COMBUSTIBLE

FACING MATERIAL

1 in.

(25 mm)

BOTTOM

OF FIREPLACE

TOP OF

FIREPLACE

EXHAUST
COLLAR

EXHAUST
PORT

SCREWS

FIREBOX

FLUE

RESTRICTOR

FLUE

RESTRICTOR

FLAPPER

DOOR

FLAPPER

DOOR

EXHAUST
COLLAR

EXHAUST
PORT

SCREWS (2)

Mount the fl ue restrictor to the fl apper door using two
screws (see Figure 7.5).