Verti-Flow™ Stoker Control

danger- risk of Fire or explosion;

DO NOT burn garbage, gasoline, drain

oil or other flammable liquids.

CautIOn- hot while in Operation;

- Keep Children Away

- Do Not Touch

how to operate the Stoker Control
There are four operator interfaces on the Stoker Control. The

operator interfaces are: one (1) rocker switch and three (3)

16-position rotary switches.
The rocker switch is a power switch that controls only the

coal feeder motor. For normal operation this switch should

be placed in the “on” position. This switch’s operation can be

verified by a small red light above the coal feeder receptacle

being on when the switch is on. The off position is used for

lighting the fire.
The other three switches are the customer’s adjustments for

the timers (on timer, off time, distribution blower time). These

switches can adjust each timer individually from 1 minute to

15 minutes in 1 minute increments. Do not set pilot mode

timers to 0.
The “on” time and the “off’ time should be programmed

to a minimum time that keeps the coal burning during the

maintenance cycling mode. The distribution blower time

should be set to 0. This is because the VF 3000 doesn’t have

a distribution blower. The Verti-Flow™ Stoker Control is also

used on the Magnum Stoker which does use this timer.
Recommended timer settings to start are: “on” 4 minutes, “off”

12 minutes, extend timer 0 minutes. You may find that these

settings produce too much heat in pilot mode. If so, you can

reduce the “on” time and increase the “off” time. However,

we do not recommend going below 4 minutes with the on

time for efficiency reasons.

the Verti-Flow™ Stoker Control
The top receptacle (0.5 A) provides power to the coal feeder

motor. Thus, the plug from the coal feeder motor should be

inserted into this receptacle.
The center receptacle (0.75 A) provides power for the

combustion blower motor. Thus, the plug from the combustion

blower should be inserted into this receptacle. The bottom

receptacle (1.25 A) is not used.
The thermostat connections on the back panel of the stoker

control are .25 inch male quick connect terminals. The

mating connectors (supplied) should be .25 inch female

quick connector terminals. The wire should be no smaller

than 22 gauge.
The thermostat connections should be connected to the

aquastat as shown on the wiring diagram.
The AC power cord should be the last connection made. The

power cord should be plugged into a 115 VAC / 60 hertz wall

outlet, which has proper grounding available. This 115 AC

volt wall outlet should also be capable of handling 3 amps

of current because this is the maximum amperage this unit

will draw.