CautIOn:

- Inspect flue pipes, joints, and seals regularly to

ensure that smoke and flue gases are not drawing

into the dwelling.

- Cleaning of the heat exchanger, flue pipe, chimney,

and draft inducer if used, is especially important at

the end of the heating season to minimize corrosion

during the summer months caused by accumulated

ash.

- DO NOT use chemicals or fluids to start a fire.
- dO nOt burn garbage, gasoline, naptha, engine oil,

or other inappropriate materials.

hopper Maintenance:

Always empty the hopper when not burning for more than

a week.
Pusher Block Maintenance:

When left standing for long periods with wet coal, the pusher

block will rust and corrode, causing it to stop. If the stoker is

then turned “on”, damage to the pusher assembly and feed

motor will result. This will be considered neglect and will void

the warranty on those parts. If the unit has not been burned

for a period of time, always check to see if moving parts are

free before using. This can best be determined by shaking

the adjuster rod.

annually:
The end of the heating season is the best time to perform

annual maintenance. Rust and corrosion can form much

faster in the high humidity of summer, so cleaning your VF

3000 will prevent those damages.
1. Remove all coal from the hopper
2. Remove all ashes
3. Remove and clean flue pipe
4. Check chimney and clean if necessary
5. Remove hopper and check for rust at bottom edges. If rust

is found, remove it with a file or sandpaper then paint the

area with spray paint available at your Harman® dealer.

6. Check the feeder for rust and corrosion where the hopper

fits into it.

7. Check pusher block to be sure it moves freely. This can

best be done by shaking the adjuster rod. If it does not

move freely, it should be removed and cleaned. Also

remove any rust or corrosion from the area where the

pusher block slides and spray with WD-40 or other rust

preventing spray. To remove pusher block, remove cover,

wing nut, adjuster and adjuster tube. Remove motor mount

with motor in place and cord still attached. Swing pusher

assembly up as high as it will go. Remove feed indicator

from side with allen wrench. Now the pusher block can be

removed. To reinstall, just reverse procedure. If the pusher

block cannot be removed, call your Harman® dealer.

warnIng- risk Of Fire;
- DO NOT Operate with flue draft exceeding -.10 in Water

Column (-24.9 Pa.)

- DO NOT operate with fuel loading or ash removal doors

open.

- DO NOT store fuel or other combustiblematerial within

specified installation clearance areas.

- INSPECT and clean chimney flue system and chimney

connectors regularly.

Adjuster Rod