Troubleshooting, Stoker control troubleshooting – Harman Coal Stoker VF3000 User Manual

Page 21

Advertising
background image

21

3-90-70741R13_05/13

troubleshooting

Feeding Problems
wet Coal:

Wet coal does not flow the same as dry coal, therefore; the

feed rate will change with wet coal. If it is too wet, it may not

feed at all. Wet coal can also cause a sulfur odor.
wrong Size Coal:

The Verti-Flow™ System is designed to burn rice coal (or

buckwheat coal if rice is not available). If buckwheat coal is

burned, raise the draft setting from .04 to .06. Larger coal

will not feed or burn properly.
hopper Blocked:

Sometimes wood, paper, or other foreign objects accidently

end up in your coal bin and can slow down or block the flow of

coal. You may have to empty the hopper to find the blockage.
Pusher Out of adjustment:

This can happen when more than one person tend the stoker.

One person does not tell the others what adjustments were

made.

Problem: No motors or lights will turn on.
Solution:
1. Check AC power cord to the stoker control
2. Check the 3 amp fuse on the side panel of the stoker

timer. (replace only with a 3 amp 3 ag slow blow fuse.)

Problem: Lights on the stoker control are on, but motors

will not operate.
Solution: Check the AC power plugs from the motors (are

they securely plugged into the correct outlet?)
Problem: One of the motors will not operate.
Solution: Check if the light above the receptacle is lit. Check

the AC power plug from the motor (is it securely plugged

into the correct outlet?”

Stoker Control troubleshooting

gas Odor Problems
gas alarm goes Off or Sulfur Odor exists:

A sulfur smell may be noticed when a door is opened during

operation with wet or damp coal. This is normal. However, it

is not recommended that wet coal be used or the doors be

opened for more than a few seconds while burning to inspect

the fire or remove ashes.
lack of draft or a down draft in the chimney: These will

cause gases to escape from the unit. No unit will function

properly without draft. Any draft problem should be corrected

before use.
A draft inducer may be installed to increase draft in marginal

situations. The installation should be performed by your

dealer who is factory trained to correct any problems on initial

start up. After proper installation, many years of trouble-free

operation can be expected.

Problem: The motors are cycling on and off, but not in the

correct order.
Solution: Check the AC power plugs from the motors (are

they securely plugged into the correct outlet?)
Problem: Coal feeder motor will not turn on.
Solution: Check if the red light is lit, if not, check if the feeder

motor switch is turned on.
Problem: The motors turn on and off as programmed, but

the water temperature is below the thermostat setting.
Solution: Check the connections from the stoker control to

the aquastat.