HP 750 User Manual

Page 105

Advertising
background image

1 Remove the window ' page 6Ć13.
2 Remove the center cover ' page 6Ć14.
3 Remove the left endcover ' page 6Ć16.
4 Remove the right endcover ' page 6Ć17.

5 Release the media sensor cable from all

the clamps. Remove the media sensor

from the entry platen.

6 Lower the rollfeed cover to the open position.
7 Loosen the wedge screws that attach the entry platen to the left and right sideplates.

Tx 15

6-53

Removal and Replacement

C4705-90000

Removing the Entry Platen

Advertising