HP 750 User Manual

Page 125

Advertising
background image

Troubleshooting

C4705-90000

8-7

Message

Error/Action

Roll misaligned
Reload roll

D Roll media is misaligned. Unload roll media. Open the roll cover

and push the media roll all the way to the right so that it is

flush against the media stop on the roll core. Reload, making

sure that the left/right media edges are flush with the left/right

edges of the roll

RS-232 error
Baud, parity

D The RSĆ232ĆC interface is configured incorrectly. Press the

Enter button to clear the message from the front panel display.

Check the baud rate and parity settings on the front panel and

in the software application configuration. Adjust the setting as

required to ensure compatibility.

D This error can also indicate a framing error caused by the

wrong number of start/stop bits sent or the wrong data word

length. The plotter expects 1 start bit, 7 data bits, 1 parity bit,

and 1 stop bit.

RS-232 error
Handshake

D The RSĆ232ĆC interface is configured incorrectly. Press the

Enter button to clear the message from the front panel display.

Check the handshake settings in the application software

configuration. Adjust the settings in the software application

configuration as required to ensure compatibility.
You cannot change the handshake setting in the plotters front panel.

Service pens
Continue

D Pen checking is ON and an error has been detected. Press the

Up Arrow button if you want to service the cartridges (replace

or reseat). Press the Down Arrow button if you want to

continue without servicing the pens.

D Pen checking is OFF and one of the cartridges is overheated.

Replace the cartridge.

Servo Processor
Initialized

D The ROM SIMM firmware is not recognized. Replace the ROM

SIMM (details ' page 6Ć7) and/or replace the main PCA (details

' page 6Ć9).

Advertising