Troubleshooting

C4705-90000

8-53

32. Button Test

The purpose of this test is to verify the operation of the frontĆpanel buttons.
Perform the button test as follows:

1 In the Service Tests submenu, scroll to 32 Button Test" and press Enter.

SERVICE TESTS

32 Button test

2 The Press any key to start test" message is displayed on the frontĆpanel.

3 Press a button on the frontĆpanel. A message stating which button was pressed will be

displayed on the frontĆpanel.

Example: If the Cancel button is pressed, the message

Cancel Pressed / Exit: Up & Down"

will be displayed on the frontĆpanel.

Press the Up and Down Arrow buttons simultaneously to stop the test.

If a button is pressed but is not shown on the front-panel display or is incorrect, then the test has
failed.

If the test fails, try

replacing one of the following components:

1 FrontĆpanel assembly ' page 6Ć18.
2 Main PCA ' page 6Ć9.

Only replace one component at a time and perform the “Button” test again before replacing
another component. Using this procedure you will be able to determine exactly which component
failed.