Honeywell ST 3000 SMART TRANSMITTER STR93D User Manual

Page 23

Advertising
background image

34-ST-03-57

Page 23


Availability

STR9xx

3D 4G

HC

e

e

H6

e

e

FF

r

r

ME

SM

CI

m

m

LZ

x

x

ZS

s

s

NE

15

15

14

14

LP

CC

15

15

21

21

WP

WX

SH

n

n

A1

n

n

A2

u

u

TB

a

a

a

a

a

a

a

a

CR

SS

B7

G1

j

j

G2

j

N1

j

j

N2

j

MB

SB

FB

Users Manual Paper Copy (Standard, HC/H6 or FF ships accordingly)

0X

h

h

TP

F1

F3

F5

F6

22

22

o

F8

16

MT

2

2

Table III continued next page

AN

DE Protocol communications

DE

b

Transmitter Housing & Electronics Options

Analog only (can be configured using appropriate Honeywell DE tool)

Communication Options (Must choose a communications option)

Over-Pressure Leak Test with F3392 Certificate

End Cap Live Circuit Warning Label in Spanish (only with ATEX 3D)

Stainless Steel Housing with M20 to 1/2" NPT 316 SS Conduit

(4 lines, 28 characters per line, customer supplied information)

SL

TC
FC

Custom Calibration and I.D. in Memory

Transmitter Configuration - (Fieldbus)

F7

Certificate of Origin (F0195)

End Cap Live Circuit Warning Label in Portuguese (only with ATEX 3D)

Certificate of Conformance (F3391)

Mounting Bracket - Carbon Steel

Calibration Test Report and Certificate of Conformance (F3399)

UM

Transmitter Mounting Brackets Options

End Cap Live Circuit Warning Label in Italian (only with ATEX 3D)

Stainless Steel Customer Wired-On Tag

b

b

TL

PG

SP

b

GE

1/2" NPT to M20 316SS Conduit Adapter (BASEEFA EEx d IIC)

NAMUR Failsafe Software

TABLE III - OPTIONS

Selection

HART 6.x Protocol Compatible Electronics

Indicating Meter Options

FOUNDATION Fieldbus Communications

HART 5.x Protocol Compatible Electronics

Teflon Coated Seal Diaphragm (1 Seal) - only for anti-sticking
Teflon Coated Seal Diaphragms(2 Seals) - only for anti-sticking

316 SS Electronics Housing - with M20 Conduit Connections

Analog Meter (0-100 Even 0-10 Square Root)

Adapter (use for FM and CSA Approvals)

Smart Meter

Gold Plated Seal Diaphragm (1 Seal)
Gold Plated Seal Diaphragm (2 Seals)

Remote Seal Options

End Cap Live Circuit Warning Label in German (only with ATEX 3D)

TG

Local Zero and Span

Local Zero

Custom Configuration of Smart Meter

Lightning Protection

SIL 2 - TÜV Certified transmitter (requires HC or H6 and WP options)

Transmitter Configuration - (non-Fieldbus)

1/2" NPT to 3/4" NPT 316 SS Conduit Adapter

Write Protection (Delivered in the "enabled" position)
Write Protection (Delivered in the "disabled" position)

Stainless Steel Customer Wired-On Tag (blank)

NACE Certificate (F0198) for welded meter bodies only

FMEDA Certificate (SIL 1) (FC33321)
SIL Certificate (SIL 2/3) (FC33337)

NACE Certificate (Process-Wetted) (FC33338)

NACE Certificate (Process-Wetted & Non-Process Wetted) (FC33339)

A286 SS (NACE) Bolts and 304 SS (NACE) Nuts for Heads

Meter Body Options

(Carbon Steel standard)

316 SS Bolts and 316 SS Nuts for Process Heads
B7M Bolts and Nuts for Process Heads

i

FG

b

Clean Transmitter & Seals for Oxygen or Chlorine Service with Certificate

b

Mounting Bracket - 304 SS

b

FE

Flat Mounting Bracket
Services/Certificates Options

A3

i

Marine Type Approvals (DNV, ABS, BV, KR & LR)

b

b

b

b

b

Advertising
This manual is related to the following products: