Fig. 9—cycle rate adjustment, Fig. 10—battery placement – Honeywell CHRONOTHERM T8624C User Manual

Page 10

Advertising
background image

10

T8624C,D

INSTALLATION

Fig. 9—Cycle rate adjustment.

SYSTEM

GRAVITY

AIR/WATER

HOT

WATER

GAS/OIL

WARM AIR

ELECTRIC

WARM AIR

1A

OUT 1/2

TO 1 TURN

OUT 1/2

TO 1 TURN

OUT 1/2

TO 1 TURN

OUT 1/2

TO 1 TURN

1B

IN

IN

(FACTORY SETTING)

IN

IN

TIME/TEMP

DISPLAY

2A

2B

24 HR

IN

12 HR

o

o

C

F

OUT 1/2

TO 1 TURN

OUT 1/2

TO 1 TURN

IN

M311A

1 SCREWS 2A, 2B AVAILABLE ON SOME MODELS ONLY.

1A

2A 2B

1B

1

CYCLES

PER HOUR

1

3

6

9

pear when thermostat is mounted back on the subbase.

IMPORTANT: For proper thermostat operation, al-

ways replace dead batteries with new alkaline
batteries. We recommend Energizer® batteries.

If batteries are completely dead, the display will go

blank when the thermostat is removed from the subbase.

After replacing the batteries, reprogramming will be nec-
essary.

BATTERY PLACEMENT
(NOTE CORRECT PLUS
AND MINUS DIRECTION)

M 372A

Fig. 10—Battery placement.

POWER OUTAGES

Backup batteries will hold the programming and keep

the display on during most power outages. Once the
power is restored, the system will resume normal opera-
tion.

If the display goes off when power is lost, either the

backup batteries need to be replaced or are not installed.
When power is restored, the display will flash 1:00 PM
as a reminder to reprogram.

MOUNTING THE THERMOSTAT

With system switch set to OFF, hang the thermostat

on the tabs at the top of the subbase (Fig. 11A). Swing
down and press on lower edge until thermostat snaps in
place (Fig. 11B). Open cover and tighten the captive
mounting screws (Fig. 11C).

SETTING DAY AND TIME

Restore 24V power to the thermostat. When power is

applied to the thermostat, the display will read 1:00 PM
and room temperature. It will go off for a few seconds,
then begin to flash on and off. Set present day and time.

Press .

Press to set the current day. Each press of

the DAY key advances the display one day.

Press TIME

or to set the current time.

If the display will not come on:
— Check the mounting of the thermostat to the sub-

base. If loose or misaligned, remove thermostat
and reinstall on the subbase, making sure it is
firmly attached.

— Check to see that heat or cool system power is on.
— Check voltage between R and C; it should be 24 to

30 Vac.

SET

PRESENT
DAY/TIME

DAY

AHEAD

BACK

Advertising