Installation instructions

Table for the choice of injectors

(*): Power calculated with inner crown operating.
(#): Power calculated with inner and outer crowns operating.

Lubrication of the gas valves

The gas valves should only be lubricated by a qualified technician.

Important!

All installation, maintenance and conversion of the appliance must be done using original factory parts.
The manufacturer declines any liability if these correct parts are not used.

Natural gas

LPG

Test Point Pressure
[kPa]

1.0

2.75

BURNER

Injector Orifice

Dia. (mm)

Gas

Consumption

[MJ/h]

Injector Orifice

Dia. (mm)

Gas

Consumption

[MJ/h]

Semi-rapid

1.12

6.30

0.70

6.30

Triple-ring wok

1.60

12.70

0.95

11.90

Dual

inner crown

0.85 (no.1 central)

3.60 (*)

0.50 (no.1 central)

3.20 (*)

outer crowns

1.15 (no.2 outer)

16.00 (#)

0.62 (no.2 outer)

13.00 (#)