3 cleaning the gas valve vent tube (if applicable), 4 adjusting burner manifold gas pressure – Frymaster 2424G User Manual

Page 12

Advertising
background image

24G SERIES FLATBOTTOM GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1-6

1.3 Cleaning the Gas Valve Vent Tube (if applicable)


1. Set the fryer power switch and the gas valve to the "OFF" position.

2. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened

for ease in removal.


3. Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any

obstruction. Remove the wire and blow through the tube to ensure it is clear.


4. Reinstall tube and bend so that the opening is pointing downward.

1.4 Adjusting Burner Manifold Gas Pressure

WARNING

This task should be performed by qualified service personnel only.


1. Ensure that the gas valve knob is in the

"OFF" position.

2. Remove the pressure tap plug from the

burner manifold.

3. Insert the fitting for a gas pressure-

measuring device into the pressure tap
hole.





4. Place the gas valve in the "ON" position then place the fryer power switch in the "ON" position.

When the burner lights and continues to burn, note gas pressure reading for correct pressure in
accordance with the table on page 1-1.





Remove pressure tap from burner manifold to
check burner manifold pressure.