Gsms – Frymaster DECATHLON H50 User Manual

Page 52

Advertising
background image

GSMS

10-3

Control Box and Related Components

ITEM

PART #

COMPONENT

1

807-1396

Relay, 24VDC SPDT (Basket Lift Relay – GSMS and GBC units only)

2

807-0680

Transformer, 208-240VAC/24VAC, 50/60 Hz, 43VA

3

807-3366

Module, Honeywell Dual-Spark FV Ignition (See NOTE below.)

4

807-0670

Relay, 24V DPDT (Heat Relay – all units)

5

106-0676SP

Cable, Ignition (used with Item 3 – also requires Item 8)

6

807-1709

Cable, Ignition (used with 807-1006 Ignition Modules)

7

806-5316SP

Wire Assembly, 20-inch High Temperature (Flame Sensor Wire)

8

807-3484

Connector, RAJAH (two required for each 807-3366 Ignition Module)

NOTE: Control box assemblies on units manufactured before October 2000 were built with

two single-spark ignition modules (P/N 807-1006). If an 807-1006 module fails, the control

box may be retrofitted with one dual-spark ignition module (P/N 807-3366) and two RAJAH

connectors (P/N 807-3484). If this option is chosen, the earlier style ignition cables (P/N 807-

1709) must also be replaced with the new ignition cables (P/N 106-0676SP).