Removing a FortiSwitch-5003A board

Hardware installation

10

Once the board is inserted correctly, fully tighten the retention screws to lock the
FortiSwitch-5003A board into position in the chassis slot.

Removing a FortiSwitch-5003A board

The following procedure describes how to correctly use the FortiSwitch-5003A
mounting components described in

“FortiSwitch-5003A mounting components” on

page 15

to remove a FortiSwitch-5003A board from an ATCA chassis slot.

FortiSwitch-5003A boards are hot swappable. The procedure for removing
a FortiSwitch-5003A board from a chassis slot is the same whether or not the
chassis is powered on.

To remove a FortiSwitch-5003A board from a chassis slot

To complete this procedure, you need:

• An ATCA chassis with a FortiSwitch-5003A board installed
• An electrostatic discharge (ESD) preventive wrist strap with connection cord

1

Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal
surface on the chassis or frame.

2

Disconnect all cables from the FortiSwitch-5003A board, including all network
cables and the console cable.

Tighten

Retention

Screw

!

Caution: Do not carry the FortiSwitch-5003A board by holding the handles or retention
screws. When inserting or removing the FortiSwitch-5003A board from a chassis slot,
handle the board by the front panel. The handles are not designed for carrying the board. If
the handles become bent or damaged the FortiSwitch-5003A board may not align correctly
in the chassis slot.

!

Caution: FortiSwitch-5003A boards must be protected from static discharge and physical
shock. Only handle or work with FortiSwitch-5003A boards at a static-free workstation.