Fabric channel interfaces – Fortinet 5003A User Manual

Page 9

Advertising
background image

FortiSwitch-5003A system

Front panel LEDs and connectors

FortiSwitch-5003A System Guide
01-30000-77803-20080917

9

Fabric channel interfaces

Table 3

lists and describes the FortiSwitch-5003A fabric channel interfaces. You

can configure fabric interface settings, group fabric interfaces into trunks, and
configure MSTP spanning tree settings for fabric interfaces from the
FortiSwitch-5003A CLI.

The fabric network activity LEDs show links and network activity for the interfaces
and connections listed in

Table 4

.

Figure 3: FortiSwitch-5003A fabric network activity LEDs

B1 and B2

Front panel gigabit base channel interfaces B1 and B2.
Use these interfaces to connect your network to the base channel, to

connect base channel 1 to base channel 2, or to connect a base channel

on one chassis to a base channel on another chassis.

BASE 10G

Front panel 10-gigabit base channel interface.
Use this interface to connect a 10-gigabit network to the base channel.

10-gigabit communication is not supported across the base channels but

this interface is still available if you need to connect the base channel to

a 10-gigabit network.

Table 2: Base channel interfaces and network activity LEDs

Interface
Name

Description

Table 3: Fabric channel interfaces

Interface Name

Description

Front Panel CLI*
2/1

slot-2/1

Interface between fabric channel 1 and fabric channel 2.
If there are two FortiSwitch-5003A boards installed in a

chassis this interface can be used to communicate between

them. In some configurations you may have to disable this

communication. See the

FortiGate-5000 Backplane

Communication Guide

for more information.

3 to 13

slot-3 to
slot-13

Fabric backplane slots 3 to 13.
The 3 to 13 fabric network activity LEDs are lit if there are

FortiGate boards in chassis slots 3 to 13.

14/F8

slot-14/f8

Front panel interface 14/F8.
Fabric backplane slot 14 and front panel interface 14/F8

share the same FortiSwitch-5003A switch port. By default the

the front panel interface 14/F8 is enabled and fabric

backplane slot 14 is disabled. You can change this setting

using a switch on the FortiSwitch-5003A board. See

“Setting

the FortiSwitch-5003A configuration switch” on page 13

.

F1 to F7

f1 to f7

Front panel 10-gigabit fabric interfaces F1 to F7.
Use these interfaces to connect your network to the fabric

channel, to connect fabric channel 1 to fabric channel 2, or to

connect a fabric channel on one chassis to a fabric channel

on another chassis.

* You can configure settings for FortiSwitch-5003A fabric interfaces from the

FortiSwitch-5003A CLI. The CLI columns show the names of the interfaces as they appear

on the FortiSwitch-5003A CLI.

Advertising