Base channel interfaces – Fortinet 5003A User Manual

Page 8

Advertising
background image

FortiSwitch-5003A System Guide

8

01-30000-77803-20080917

Front panel LEDs and connectors

FortiSwitch-5003A system

Base channel interfaces

Table 2

lists and describes the FortiSwitch-5003A base backplane channel

interfaces. The base backplane interfaces are not configurable or visible from the
FortiSwitch-5003A CLI.

Figure 2: FortiSwitch-5003A base network activity LEDs

BASE 10G, 14/F8, F7,
F6, F5, F4, F3, F2, F1
(Base and Fabric 10
gigabit LEDs)

Solid

Green

Indicates this interface is connected to a 10-gigabit

network device with the correct cable and the

attached network device has power.

Blinking

Green

Indicates 10-gigabit network traffic on this interface.

Off

No link.

HS (Hot Swap)

Blue

The FortiSwitch-5003A is ready to be hot-swapped

(removed from the chassis). If the HS light is blue

and no other LEDs are lit the FortiSwitch-5003A

board has lost power.

Flashing

Blue

The FortiSwitch-5003A is changing from hot swap to

running mode or from running mode to hot swap.

This happens when the FortiSwitch-5003A board is

starting up or shutting down.

Off

Normal operation. The FortiSwitch-5003A board is in

contact with the chassis backplane.

Table 1: FortiSwitch-5003A front panel LEDs and switches (Continued)

LED

State

Description

Table 2: Base channel interfaces and network activity LEDs

Interface
Name

Description

SH1

If the FortiSwitch-5003A board is in the first hub/switch fabric slot, this

LED indicates a backplane connection to shelf manager 1. If the

FortiSwitch-5003A board is in second hub/switch fabric slot this LED

indicates a backplane connection to shelf manager 2.
This LED may not be lit even if a shelf manager is present if the shelf

manager is configured to use its front panel interface.

15 and SH2

Not used.

2/1

Base channel connection between base channels 1 and 2.
The 2/1 LED is lit if there is any board capable of connecting to the base

channel in the other slot. For example, if the FortiSwitch-5003A board is

installed in the first hub/switch fabric slot, this LED will be lit if any board

is installed in the second hub/switch fabric slot, including a

FortiSwitch-5003A board or any FortiGate-5000 board.

3 to 14

Base channel connection to FortiGate-5000 boards in chassis slots 3 to

14.

Advertising