1. The first four items show the upstream and

downstream test speeds (Speed), the duration of the
test (Duration), the frame length (Frm Len), and the
data pattern (Pattern) as selected on the Throughput
Test configuration display.

2. The

Upstream

and Downstream rates show the

actual data upstream and downstream transmission
rates used during this Throughput Test excluding the
Ethernet overhead of preamble and inter-frame gap.
The number of frames (# Frms) shows the number of
frames successfully transmitted and the percentage
of successful transmissions. The number of frames
lost (# Lost) shows the number of frames lost during
transmission.

3. The bottom of the display shows the addresses used

for the local unit (This IP or ATU-R IP for xDSL), the
unit at the remote end (Rmt IP or ATU-C IP for
xDSL), and the router (Routr IP -- if any).

4. Hops are the number of routers (hops) between the

remote unit and the local unit.

1

2

3

4

ace706f.eps

Figure 7-8. Final ITO Throughput Test Results