Frymaster Electric Cooker 8C User Manual

Page 18

Advertising
background image

5-2

ON UNIT WITH AUTOFILL,

COOKPOT DID NOT FILL

WHEN UNIT WAS

TURNED ON. WATER

SUPPLY TO UNIT

VERIFIED TO BE ON.

Did anything

appear in controller

display when unit was

turned on?

Disconnect unit from

electrical power. Check

the left 5-amp fuse in

component box. Replace

fuse if blown then attempt

to operate.

Did unit begin

to fill?

Probable causes are shorted

upper water level sensor, failed

water solenoid, or loose/

damaged wiring. Call FASC.

No

No

NOTE: IF AUTOFILL WORKS

BUT AUTOSKIM DOES NOT,

PROBLEM IS A FAILED

CONTROLLER. ORDER

REPLACEMENT FROM FASC

OR DISTRIBUTOR.

Clean the water

level sensors.

Is another

controller, known

to be working,

available?

Substitute the controller
known to be working for

the suspect controller and

attempt to operate unit.

Yes

No

Problem resolved.

Yes

Yes

Yes

Problem is beyond

the scope of operator
troubleshooting. Call

FASC.

No

No

Problem is a failed

controller. Order

replacement from

FASC or distributor.

Yes

Did unit begin

to fill?

Did unit begin

to fill?

Advertising