14 technician troubleshooting guides (continued) – Frymaster Electric Cooker 8C User Manual

Page 38

Advertising
background image

6-14

Technician Troubleshooting Guides (Continued)

On 8SMS and 8BC units, is 13-17VDC

present at pin 10 when lift is in UP position

and zero VDC when lift is in DOWN

position?

TROUBLESHOOTING

THE CONTROLLER

Is 24VAC

present at pin 1?

Is 24VAC present at pin 4 when

off and zero VAC when calling for

heat?

Yes

Yes

Is 24VAC present at pin 6 when
not filling and is pin 6 grounded

when filling?

Are the fuses in

the component

box OK?

Replace fuse.

No

Yes

Yes

Is 24VAC

present on

transformer
secondary?

No

No

Replace transformer.

On 8SMS and 8BC units, is

13-17VDC present at pin 12?

Yes

Is 2-3VDC

present at pin 13?

Yes

Controller is OK.

Yes

Replace controller.

No

No

No

No

No

Advertising