15 technician troubleshooting guides (continued) – Frymaster Electric Cooker 8C User Manual

Page 39

Advertising
background image

6-15

Technician Troubleshooting Guides (Continued)

Before performing the following checks, disconnect the unit from the
electrical power source and check all wiring connections involved to
ensure they are secure.

Each of the following checks is to be performed with the unit connected to the
electrical power supply, with the controller on and calling for heat, and with
enough water in the cookpot to cover the lower water level sensor.

TROUBLESHOOTING

THE CONTACTOR

COIL

Is 24VAC

present at pin 4 of the 15-

pin plug when controller is

calling for heat?

Probable cause is

failed controller.

No

Is button in the

center of the contactor

block depressed?

Contactor coil is

OK. Element has

failed. Replace.

Yes

Yes

Contactor coil has

failed. Replace.

No

TROUBLESHOOTING

THE TEMPERATURE

PROBE

What is the

problem?

Water boils in

simmer mode.

Water temperature

is too low in

simmer mode.

Check for shorted probe circuit.
Probe voltage at pin 13 should be:
Approx 1.8VDC @ 60ºF (16ºC)
Approx 2.0VDC @ 100ºF (38ºC)
Approx 2.5 VDC @ 212ºF (100ºC)
Probe resistance should be:
Approx 552 ohms @ 60ºF (16ºC)
Approx 655 ohms @ 100ºF (38ºC)
Approx 1000 ohms @ 212ºF (100ºC)

TROUBLESHOOTING

THE HIGH-LIMIT

THERMOSTAT

Is 24VAC

present at the C

terminal of the

high-limit?

High-limit has

failed. Replace.

High-limit is OK.

Yes

No

Are readings

within

specifications?

Probe is shorted.

Replace.

Check continuity

of probe.

Continuity OK?

Probe is OK.

Calibrate

controller.

Yes

Yes

No

Probe is open.

Replace.

No