background image

6-13

Technician Troubleshooting Guides (Continued)

TROUBLESHOOTING

THE BASKET LIFT

With the basket lift

in the UP position, is 13-17VDC

present at pin 10 of 15-pin plug (0

volts if in DOWN position)?

Probable cause is a

failed controller.

No

With the basket lift

in the UP position, is 13-17VDC

present at relay terminal A (0 volts

if in DOWN position)?

Yes

Probable cause is

failed/loose wiring.

No

Yes

With the basket lift in the same

position as for the previous check, is line

voltage present at the Common (upper)

terminal of switch?

With the basket lift

in the UP position, is line voltage

present at the NC (lower) terminal of the

microswitch (middle terminal if in

DOWN position)?

Probable cause is a

failed relay.

No

Probable cause is a

failed switch.

No

Probable cause is a

failed motor.

Is 3-Amp

fuse in the

component box

OK?

Replace fuse.

No

Yes

Yes

Yes

If the basket lift motor is activating, but the basket lift fails to raise
or lower, or if its movement is erratic, the probable cause is
jamming or binding of the basket lift rod. Apply a light-weight
white grease (such as Lubriplate

T M

) to the rod. If this does not

correct the problem, check for a bent or otherwise damaged rod and
link, and for a loose bellcrank.