SUPER RUNNER SERIES GAS FRYERS

CHAPTER 1: INSTALLATION INSTRUCTIONS

1-3

AUSTRALIAN REQUIREMENTS:


To be installed on a firm, level surface in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any
other relevant statutory regulations. The Australian orifice size and manifold pressures are listed below for the SR62.

Model

Gas Type

Orifice Size

Manifold Pressure KPa

Manifold Pressure Inches WC

SR62

Nat

2.53 mm

0.9 KPa

3.6”

SR62

Prop

1.6 mm

2.4 KPa

9.6”

CE UNITS ONLY:

Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity/Color, Burner Markings
and Pilot Markings are listed in the table below:

MANIFOLD GAS PRESSURE

MODEL*

NOMINAL

HEAT INPUT-

Qn

(kW)

GAS TYPE

ORIFICE

SIZE (MM)

MBAR INCH

W.C.

ORIFICE

QTY/ COLOR

BURNER

MARKING

PILOT

MARKING

SR62 GM

37.5

G20
G25
G31

2.40
2.40
1.51

12,0
17,5
22,0

4,8
7,0
8,8

5/BLUE
5/BLUE

5/RED

Blue
Blue

Red

26N
26N

16LP

SR52 GM

30

G20
G25
G31

2.40
2.40
1.51

12,0
17,5
22,0

4,8
7,0
8,8

4/BLUE
4/BLUE

4/RED

Blue
Blue

Red

26N
26N

16LP

SR42 GM

26

G20
G25
G31

2.40
2.40
1.51

12,0
17,5
22,0

4,8
7,0
8,8

3/BLUE
3/BLUE

3/RED

Blue
Blue

Red

26N
26N

16LP

*SR prefix- Super Runner Series

*GM suffix- gas millivolt system with no electrical supply connections

required

NON-CE UNITS ONLY:


Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity, and Pilot Markings are
listed in the table below:

MODEL*

NOMINAL

HEAT INPUT-

Qn

(BTU)

GAS TYPE

ORIFICE

SIZE (MM)

MANIFOLD GAS

PRESSURE

(INCH W.C.)

ORIFICE

QUANTITY

PILOT

MARKING

SR62 GM

150

NAT

LP

2.53(#39)
1.51(#53)

4

11

5
5

26N

16LP

SR52 GM

120

NAT

LP

2.53(#39)
1.51(#53)

4

11

4
4

26N

16LP

SR42 GM

105

NAT

LP

2.80(#35)
1.70(#51)

4

11

3
3

26N

16LP

*SR prefix- Super Runner Series

*GM suffix- gas millivolt system with no electrical supply connections required

NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is
operating.

1.4 Connection to the Gas Supply Line

NOTE: The gas supply (service) line must be the same size or greater
than the fryer inlet line. This appliance is equipped with a ½-inch (15-
mm) inlet. The gas supply line must be sized to accommodate all gas-
fired equipment connected to the line. Consult the local gas company
or supplier, or your local contractor for minimum supply line
requirements.

NOTE: If quick-disconnect supply lines or flex lines are used,
increase supply line size to ¾-inch (22-mm) or larger.


Propane Applications;

Proper Regulator Must Be Installed