Frymaster Series SR62 User Manual

Page 8

Advertising
background image

SUPER RUNNER SERIES GAS FRYERS

CHAPTER 1: INSTALLATION INSTRUCTIONS

1-6

Frypot Assembly

Gas Valve

Manifold Support Bracket

Gas Burner

See Detail A

Pressure

Test

Spigot

Orifice

Temperature

Control

Gas

Manifold

Assembly

1/2—3/4 Reducer

Bushing

Burner

Gas Manifold

Burner/Orifice Location

Detail A

Orifice

1.30-inch [33-mm]

1.63-inch [41-mm]



1.6 Gas Conversion Components

Use the following components to convert from natural gas to propane and vice-
versa. See Section 1.5 for orifice quantities required for conversion.






Natural Gas to Propane Kit. 826-1817

Propane To Natural Gas Kit, 826-2017

Bushing, NPT Flush, SR 42 series only

Bushing, NPT Flush, SR 42 series only

Pilot Orifice (16LP) CE & Non-CE

Pilot Orifice (26N) CE & Non-CE

Burner Orifice, 1.51mm- CE ONLY: All Super Runner
Series

Burner Orifice, 2.40mm- CE ONLY: All Super Runner
Series

Burner Orifice, 1.51mm (#53)- NON-CE ONLY: SR52
& SR62 Series Only

Burner Orifice, 2.53mm (#39)- NON-CE ONLY: SR52
& SR62 Series Only

Burner Orifice, 1.70mm (#51)- NON-CE ONLY: SR42
Series Only

Burner Orifice, 2.80mm (#35)- NON-CE ONLY: S42
Series Only

Rating label, contact factory at time of conversion

Rating label, contact factory at time of conversion

* Burner orifices listed above are for fryers operating at altitudes of 2000 feet (610 meters) or less. For altitudes
greater than 2000 feet (610 meters), contact the factory for the correct orifice size.

Typical gas valve, burner and orifice locations (SR42 shown above).

Propane Applications:

Proper Regulator Must Be Installed

Advertising
This manual is related to the following products: