TB14 SERIES GAS FRYERS

CHAPTER 5: BUILT-IN FILTRATION

5-10

5.4.2 Filter Operation (cont.)

4. After ensuring the filter pan is correctly

positioned under the drain tube, and the pan-
disconnect is properly connected, pull the red
handle to drain the frypot into the filter pan.

5. After all oil/shortening has drained from the

frypot into the filter pan, pull the yellow
handle to open the oil return line and activate
the filter pump.

Note: The filter system is equipped with a
filter by-pass switch that will activate the
filter system in case of return-microswitch
failure (see section 5.3.1, page 5-6 for
details).

Pull the red handle to open the drain valve.

Pull the yellow handle to open the oil return valve
and activate the filter pump.