background image

5-6

5.6 FILTER OPERATION (cont.)

5. Move the oil-return handle from left to right to

open the oil-return line. The filter pump will
activate.

6. If the filter pump does not activate when the

oil-return handle is opened, check the circuit
breaker to see if it needs resetting. If the
circuit breaker cannot be reset, see page 5-
10 for filtration system troubleshooting.

7. Polishing: Leave the fryer drain valve open

for approximately 5 minutes and allow the oil
to circulate through the frypot, back into the
filter. Polishing extends oil life and improves
cooking flavor.

8. Close the fryer drain valve. The frypot will

begin to fill.

9. Allow the filter to pump bubbles into the fryer

for 15-30 seconds to clear the oil return lines.

10. Close the oil-return handle to shut filter pump

off.

UFF filter pump circuit breaker.

Allow the oil to bubble for 15-30 seconds after
the filter pan is empty to clear the oil-return lines.

LJS 24G oil-return handle location.