Mechanical Seal Replacement
(refer to Figures 7 and 8)

This procedure is best completed with the pump held in
a vertical position, motor down.

First complete “Disassembly” instructions 1 through 5
under “Impeller Stack Replacement.” (see Figure 7).

6. Remove 4 capscrews holding pump body to motor.

Pump handle will come off with top capscrews.

7. Unscrew pump shell from pump body, turning clock-

wise (left hand threads).

8. Remove mechanical shaft seal spring and rotating

half from motor shaft. Use care not to scratch motor
shaft when removing rotating half.

9. Remove pump body from motor and place on flat

surface, face down. Again, use care not to scratch
motor shaft.

10. Use a screwdriver to push ceramic seat out from seal

cavity as shown.

11. Installation of ceramic seat:

A. Turn pump body over so seal cavity is up; clean

cavity thoroughly.

B. Clean polished surface of ceramic seat with a

clean cloth.

C. Lubricate outside rubber surface of seat with soapy

water. Place cardboard washer over polished face

of seat and press into seal cavity using a 3/4” sock-
et or a piece of 3/4” standard pipe.

D. Be sure polished surface of seat is free of dirt and

has not been damaged by insertion. Remove
excess soapy water. Dispose of cardboard washer.

12. Installation of rotating half and spring:

A. Reinstall pump body on motor using extreme cau-

tion not to hit ceramic portion of seal on motor
shaft. Reattach pump body to motor using cap-
screws. Be sure to reinstall pump handle at this
time.

B. Inspect shaft to make sure that it is clean.

C. Clean face of rotating half of seal with a clean

cloth.

D. Lubricate inside diameter of rotating half with

soapy water and slide onto motor shaft (sealing
face first).

E. Place spring over motor shaft so it rests on rotating

half.

13. To complete reassembly from this point, reverse

instructions 1 through 5 under “Impeller Stack
Replacement.”

NOTICE: Lubricate suction and discharge O-Rings
with soapy water for easier installation of shell.

Ceramic Seat

3/4" pipe or
3/4" socket
with extender

Polished
Face

Rotating
Half

Cardboard
washer (supplied
w/seal)

Rotating Half
of Mechanical
Seal

Remove shell;
turn clockwise.

Push ceramic
seat out of
pump body

Remove
Pump Body

6

8

7

9

10

11

12

1212 0894

Figure 8 – Mechanical seal replacement.