48 alarms – Furuno FR-1500 User Manual

Page 58

Advertising
background image

-1.44-

1.48 Alarms

The table below summarizes alarms which may occur at various warning conditions.

Warning Audible

alarm

Visual alarm

To quit alarm status

HEADING

failure

2 beeps

HDG label reads xxx.x° and the
message GYRO SIG MISSING

appears in red.
Display is automatically switched

to head-up mode within 1 min.

When the heading signal from
the gyrocompass restores

normal, the indication HDG SET
appears in red.

Match the on-screen HDG
readout with the actual compass

reading, if necessary. To stop
the audible alarm press the

AUDIO OFF key.


Press the MODE key to erase

HDG SET and correct the
heading readout.

Target alarm

(TAZ)

Beeps

Target flashes.

Press [TARGET ALARM] key.

WATCH alarm Beeps

WATCH 0:00
(Label WATCH TIM turns red

and time count freezes at 0:00).

Press the [AUDIO OFF] key.
The label WATCH turns to

normal video and the timer is
reset.

Own ship

lat/lon

Cursor lat/lon

None

xxx.x° In own ship position field
xxx.x° In cursor position field

Make sure that own ship
position data is fed from

external radionav equipment.

System failure None

Message AZIMUTH SIGNAL

MISSING appears. No radar
echoes.

Incorrect

keystroke

Double
beep tone

None

Correct keystroke creates a
single beep provided that KEY

BEEP ON is selected in initial
settings.

Log failure

2 beeps

LOG xx.x and LOG SIGNAL
MISSING appear, if a log signal

is absent for 30 sec while an os

speed has been > 5.0 kt.

If the SDME has failed, use the
Manual Speed mode or other

appropriate sensor.

EPFS failure

Continuous

beep

EPFS in red (EPFS: electronic
position-finding system)
The indication also appears
when the GPS mode is
switched between GPS and
DGPS.

To silence the beep, press the
[AUDIO OFF] key.

TRUE VECTOR

indication

None

TRUE VECTOR (red) appears in
the second data cell when the
presentation mode is RM, goes
off in the North-up TM.

UPDATE PLOT None

If you have failed to enter a
next EPA plot within 10 min,
this indication flashes. Plot
symbol of the target also
flashes.

Re-acquire the flashing target

within 5 min. Leave it if it is not
important.

COLLISION Continuous

beep

COLLISION comes on when
EPA- or ATA-tracked target is
on collision course.

Take evasive action or

terminate tracking of target.
Then, visual indication goes off.

Advertising