2 life expectancy of major parts, 3 replacement of batteries – Furuno FR-1500 User Manual

Page 88

Advertising
background image

-5.2-

Terminal

strips

and plugs in
antenna unit

Open antenna cover to
check terminal strip and plug
connections inside. Also
check the rubber gasket of
antenna covers for
deterioration.

When closing antenna covers
in position, be careful not to
catch loose wires between
covers and unit.

6 months
to one
year

CRT and
surrounding
components

High voltage at CRT and
surrounding components
attract dust in environment
which will cause poor
insulation. Ask your nearest
FURUNO representative or
dealer to clean internal
high-voltage components.

If CRT anode rubber cap or
wire sheath is cracked, ask
your dealer to replace it. Wait
for at least 3 minutes until high
voltage components (CRT and
HV capacitors) discharge their
residual charges before
accessing them.

Terminal

strips,

sockets, earth
terminal

Check for loose
connections. Check contacts
and plugs for proper seating,
etc.

5.2 Life Expectancy of Major Parts

Parts Type

Life

expectancy Remarks

Antenna motor D8G-571 (X-band) 42 rpm

D8G-571 (X-band) 24 rpm

Gears more than 10,000 h Wind load 100 kt

Magnetron

MG5389, X-band, 6 kW

MAF1422B, X-band, 6 kW
MG4006, X-band, 6 kW
MAF1425B, X-band, 12 kW
MG4010, X-band, 12 kW
MG5436, X-band, 25 kW

2,000 - 3,000 h

5.3 Replacement of Batteries

The GYRO CONVERTER Board (option) and the RP Board have a battery. The battery for the RP
Board preserves data when the power is turned off, and its life is about five years. When the
battery voltage of the battery on the RD Board is low, NG (No Good) appears at the diagnostic test
for the RP board. When this happens, contact your dealer to request replacement of the battery.

Advertising