2 OPERATION OF AUTOMATIC TRACKING AID (ATA) ARP-17

2.1 Introduction

The FR-1500 MARK-3 series radar can accommodate an optional ATA (Automatic Tracking Aid)
module complying with IMO MSC.64(67) Annex 4 and IEC 60872-2. With the optional ATA circuit
board (ARP -17) fitted in the display unit, the radar will automatically acquire 10 targets coming into
the acquisition area. Once a target is acquired automatically or manually it is automatically tracked
within 0.2 to 32 nm, whether inside or outside the acquisition area.

Principal specifications
Auto tracking range: 0.1 - 32 nm, irrespective of range scale and acquisition range
Vector length:

0.5 sec., 1, 2, 3, 6, 12, 15, 30 min.

Orientation:

True velocity or relative velocity

Stabilization:

Sea or Ground stabilization

Motion trend:

Displayed within 20 scans, full accuracy within 60 scans after acquisition.

Past positions:

10 past positions at intervals of 30 sec, 1, 2, 3 or 6 min.

Alarms:

Visual and audible alarms against targets violating CPA/TCPA limits, lost
targets, targets crossing guard zone, system failure and target full status.

ATA Menu tree

MENU key --------------- 1. VIDEO PLOT/AIS* Requires RP-17 or RP-180. AIS not shown on RP-17

------- 2. TGT TRAIL

------- 3. TGT ALARM

------- 4. WATCH TIME

------- 5. ECHO SIG

-------

6. FUNC

------- 7. PLOT-------------------1. MARK DISP (OFF/ON)

------- 8. MARK

----- 2. ERASE

------- 9. BRILL

----- 3. VECT REF (REL/TRUE)

------- 0. OTHERS

----- 4. VECT TIME (30SEC/1/3/6/15/30MIN)

----- 5. CPA SET (OFF/0.5/1/1.5/2/3/4/5/6NM)

----- 6. TCPA SET (30SEC/1/2/3/4/5/6/12/15NM)

----- 7. TRACK (ON/OFF)

----- 8. AUDIO ALARM (OFF/ON)

----- 9. INTVAL (30SEC/1/2/3/6 min)

-----

0.

----------------1. ↑

-----2. AUTO ACQ (OFF/ON/SET)

-----3. GUARD ZONE (OFF/ON/SET)

-----4.

TRACK

TEST

-----5. LAND DISCRIM (0/1/2/3/4)

-----6.

TTM

(OFF/REL/TRUE)

-----7. VECTOR START (1 min/20 scans)

-----8. REF TGT VECTOR (OFF/ON)

-----9. TARGET BASED SPEED