Frymaster BIH1721 User Manual

Page 29

Advertising
background image

EH1721 SERIES ELECTRIC FRYERS

CHAPTER 4: BUILT-IN FILTRATION

4-10

4.3.2 Filter Operation (cont.)

11. Three-battery and larger systems may come

equipped with an optional drain flush. After
filtering frypot #3 (farthest from the filter) for
5 minutes, close the oil return valve to stop
the filtering process. Do not refill the frypot.
Close the drain valve (red handle) on the
frypot being filtered. Ensure all other valves
(red and yellow handles) are closed. Pull the
blue handle to open the flush valve. After the
drain line is clear of sediment (approximately
2 minutes), push the blue handle to close
flush valve. Open the oil-return valve
(yellow handle) to refill the frypot.




DANGER

The crumb tray in fryers equipped with a filter system must be emptied into a

fireproof container at the end of frying operations each day. Some food particles

can spontaneously combust if left soaking in certain shortening material.

WARNING

Do not bang fry baskets or other utensils on the fryer’s joiner strip. The strip is

present to seal the joint between the frypots. Banging fry baskets on the strip to

dislodge shortening will distort the strip, adversely affecting its fit. It is designed for

a tight fit and should only be removed for cleaning.

Drain-flush handle (blue) location.

Advertising