10. Attach the EMI cores supplied as shown below.

J806

J805

J803

J804

J802

J801

Motor

J613

J611

J1

EMI core
E04SS251512
(Above cable
clamping
plate)

Cable
entrance

IF9214

IF9214A

PTU-9335

MD-9208

Cable
clamping plate

How to attach EMI core

11. Fix the shield cover. Do not pinch the cable.
12. Attach the radome cover, aligning triangle mark on radome cover with that on radome

base.

Radome cover

Radome base

How to position the radome cover

13. Loosely fasten the radome fixing bolts. You will tighten them after confirming magnetron

heater voltage.

Advertising