Dj-1, Ground terminal, Data1 to data4 – Furuno MARINE RADAR 1823C User Manual

Page 38

Advertising
background image

2-2

12-24 VDC

Connect the power cable to the POWER connector at the back of the display unit.

DJ-1

For MODEL1823C/1833C/1933C/1943C/1953C, remove the waterproofing cap from DJ-1
port and discard it.

MODEL1823C/1833C:

Connect the MJ-B24LPF0002 cable from the
antenna unit to this port.

MODEL1933C/1943C/1953C:

Connect the MJ-B24LPF0005 cable from the
power supply unit to this port.

GD-1900C:

Do not remove the waterproofing cap.
Wrap the connector nut and cap with vinyl tape as
shown below.

Connector nut (for 24P)

Waterproofing cap (yellow)

Vinyl tape

Waterproofing cap and connector nut, sectional view

Ground terminal

Connect the ground wire (local supply, IV-2sq) between the ground terminal and ship’s
ground.

DATA1 to DATA4

Other equipments can be connected here as shown below.

DATA1 (7P)

DATA2 (6P)

DATA3 (6P)

DATA4 (7P)

GPS receiver
GP-310B/320B

NMEA sentence
(ex. Navaid)

Heading sensor (ex. SC-60/120)
(MODEL series only)

External buzzer,
PC, NMEA IN (Echo
sounder)

This equipment can receive the following NMEA 0183 format sentence from other
equipments.

Own ship’s position:

GGA>RMC>RMA>GLL

● Time: ZDA

Ship’s speed:

RMC>RMA>VTG>VHW

● Other ship’s information: TTM

● Insight satellite information: GSV

● Wind speed and angle:

Heading

(True):

HDT>HDG>HDM

MWV>VWT/VWR

Course: RMC>RMA>VTG

Depth: DPT>DBT

Temperature:

MTW

You will need the optional NMEA cable to connect with other equipments (E/S, navaid, etc.).